Dirty Systems – No Legionella – Why?

CELL MUTATIONS

There are many occasions when we come across a dirty water systems with all the characteristics to provide a perfect environment for legionella bacteria to thrive. However, when we sample these water systems, we may get high readings on our TVC tests, along with other waterborne bacteria, but nothing on the legionella counts.

There can be multiple reasons for this. Maybe the 1000ml water sample taken remotely from the outlet / drain valve just simply did not capture any legionella via shear luck. Maybe the system in the areas sampled does not support the life of legionella bacteria for physical reasons. Maybe the legionella had been flushed out the outlet prior to sampling. Maybe the environment is more favorable to the other bacteria present and the growth of the other species will accelerate. This will starve the legionella of the nutrients and oxygen they need to thrive in the system. They are all possibilities, but there is another reason that could be the cause.

MUTATIONS

Most mutations are harmful to the organism possessing them, and so that individual dies. The presence of lots of other bacteria will inevitably result in lots of dead DNA fragments floating around the water system and sticking to biofilms and within rubbers seals and strainers within the plumbing. These DNA fragments can be absorbed via the legionella cell membrane which in most cases will result in the legionella dying. In this scenario, the legionella will struggle to proliferate and multiply as the dead bacteria DNA is acting like a biocide (figuratively speaking).

It may also mutate and become a different DNA make up all together. If this mutation changes the DNA make up and the characteristics of the bacteria, it may result in a negative sample, despite the fact legionella is indeed in the system in very small numbers. This is particularly the case if the analysis is being carried out via PCR. If the bacteria has mutated but still holds most of its physical characteristics, it will probably still be recognisable under the microscope.

The image below shows how mutation can occur.

RESISTANT BACTERIA

Occasionally, a mutation can occur that is beneficial to the organism. In the case of microbes, this could be a mutation in a gene which allows the microbe to survive in the presence of certain strengths of disinfection, i.e. to be resistant to low levels of chemicals and higher temperatures within the water systems.

The new gene (mutant) can spread very rapidly, as every offspring of the resistant microbe has an exact copy of the DNA and so will also carry the new gene. Therefore, you may get a better survival rate of bacteria at higher temperatures if successful mutation has occurred. This may result in high TVC counts despite controls seeming reasonable at face value.

This can be one of the reasons that multiple disinfections and high temperature thermal disinfections need to be carried out to help eradicate the system of all bacteria present.

Leave a Reply

Find out how we can help you!

With our extensive experience in Legionella Risk Assessment Services & Water Treatment Services Contact us today to find out how we can help you.

Contact Us

Thermostatic Mixing Valves (TMVs): Understanding TMV2, TMV3 and Your Legal Responsibilities

Thermostatic Mixing Valves (TMVs) play a critical role in controlling water temperature and reducing the risk of scalding in both domestic and commercial buildings. In higher-risk environments such as healthcare, care homes and education settings, correct valve selection, installation and ongoing maintenance is not just best practice – it is a legal and moral responsibility…. Read more »

How Passing TMVs Drive Legionella and Biofilm Formation

Passing TMVs create the exact conditions Legionella bacteria thrive in. The combined effects include: Once temperature control is lost, biofilm rapidly develops on internal pipe surfaces. Biofilm acts as: As biofilm thickens, it further restricts flow, worsening stagnation and creating a self-reinforcing cycle that accelerates colonisation. In many investigations of persistent Legionella positives, passing TMVs… Read more »

Meet our two Colleagues of the Year!

Winner – North Team: Maddie Smout It is with huge pleasure that we announce Maddie Smout as this year’s Colleague of the Year for the North team, an award that is entirely driven by colleague nominations, making it all the more meaningful. The feedback received about Maddie was overwhelming, consistent, and incredibly heartfelt. Time and… Read more »

Why Hot Water Circulation Failures Remain the Hidden Weakness in Legionella Risk Assessments and Where Remote Monitoring Fits In

Hot water circulation, or more accurately the absence of it, remains one of the most critical areas of focus for any competent Legionella risk assessor. Despite its importance, it continues to be overlooked in the majority of risk assessment documents produced across the industry. Alarmingly, this issue is not confined to inexperienced assessors; it appears… Read more »